Product 3/16

Fronius IG Plus 10.0 Grid Tie Inverter 9995 Watt

$5,849.00

The Fronius IG central inverters are suitable for pv systems starting with an AC output power of 24 kW and work with a completely new system configuration. There is not only one power stack converting the electricity but also 9, 12 to 15 printed circuit boards that share the work, depending on the output class.

The reason for this is that it is well-known that the energy yield increases in part-load areas if smaller power stacks are operated at higher capacity. Therefore, every Fronius IG central inverter works with several smaller power stacks that switch on or off completely automatically depending on irradiance so that they can always deliver maximum power.

INPUT DATA:
Recommended PV-Power (Wp) 8500 - 11500 Wp
MPPT - Voltage range 230 - 500 V
Max. Input voltage range

(at 1000W/m2 14F (-10C) 600V

Max. usable DC input current 13.6 A
Nominal Input Current 27.6 A
Max. usable Input Current 46.7 A
Admissible conductor size (DC) No. 14-6 AWG
OUTPUT DATA
Nominal output power (PAC nom) 9995 W
Max. continuous output power (104F 208 V / 240 V/ 277 V) 9995 W
Nominal AC output voltage 208V / 240V / 277V
Operating AC voltage range (default): 208V 183 - 229 V
Maximum continuous output current: 208 V 48.1 A
Admissible conductor size (AC) No. 14 - 4 AWG
Max. continuous utility back feed current 0 A
Nominal frequency 60 Hz
Operating frequency range 59.3 - 60.5 Hz
Total harmonic distortion < 3 %
Power factor 1
GENERAL DATA
Max. Efficiency 96.2 %
CEC Efficiency: 208 V 95.0 %
Consumption in standby (night) < 1 W
Consumption during operation 22W
Cooling Controlled forced ventilation, variable fan speed
Enclosure Type NEMA 3R
Dimensions (W x H x D) 17.1 x 48.1 x 9.6 in
Power Stage Weight 82 lbs
Wiring Compartment Weight 26 lbs
Admissing ambient operating temperature -4 ... 122F
SAFETY EQUIPMENT
Ground fault protextion Internal GFDI; in accordance with UL 1741-2005 and NEC Art. 690
DC reverse polarity protection Internal diode
Islading Protection Internal; in accordance with UL 1741-2005, IEEE 1547-2003
Over temperature Output power derating / active cooling

This product was added to our catalog on Thursday 12 August, 2010.