Hello,
Sign In
or
Register a new account
Twitter
Facebook
Contact Us
About Us
Newsletter
Blog
Sun Electronics
Miami Offices:
(786) 565-9368
(786) 955-6027
(786) 955-6198
(786) 955-6147
(786) 565-9359
(305) 536-9917
Miami Fax:
(786) 565-9375
Miami Warehouse:
(786) 565-9368
(786) 955-6027
Shanghai
+602-908-1309
Phoenix Offices:
(623) 849-1338
(623) 848-1458
Puerto Rico:
(786) 709-3850
PV Systems
Grid-Tie
Grid-Tie with Battery
Off-Grid
Backup Systems
Warehouses
Miami Warehouse
Phoenix Warehouse
Puerto Rico Warehouse
Jamaica Inventory
Bahamas Warehouse
Europe Inventory
Canada Inventory
Installations
Testimonials
Systems with Sun Modules
Systems with Evergreen Modules
Systems with Kyocera Modules
Systems with Kaneka Modules
Tools
Best Incentives
Calculator
Videos
Contact Us
Blog
Technical Center
Solar Products Categories
Solar Panels
Solar Laminates
PV Systems->
Inverters & Chargers
->
|_ Grid-Tie Inverter
|_ Grid-Tie Inverter/Chargers
|_ Off-Grid Inverter
|_ Off-Grid Inverter/Chargers
Inverter Accessories
Freezer & Refrigerator
Appliances
Backup Power
Batteries for Solar
Battery Chargers
Breakers and Fuses
Cables & Wires
Charge Controllers
Combiner Boxes
Generators
Panel Mounting
Wind Turbines
Solar Cells
Books and Training DVDs
Solar Toys
Your Own Solar Electric Business
All Products ...
Prev
Product 2/17
Next
Fronius Grid-Tie Inverter IG 2000
$1,527.00
$1,398.00
Save: 8% off
Click For Larger Image
Fronius IG 2000: (030-03402)
INPUT DATA:
Recommended PV-Power (Wp)
1500 - 2500 Wp
Max. DC input voltage
500V
Operating DC voltage range
150 - 450 V
Max. usable DC input current
13.6 A
AC OUTPUT DATA
Maximum output power @ 40 C
2000 W
Nominal AC output voltage
240 V
Utility AC voltage range
212 - 264 V (240 V + 10% / -12%)
Maximum AC current
8.35 A
Maximum utility back feed current
0.0 A
Operating frequency range
59.3 - 60.5 Hz (60 Hz nom)
Total Harmonic Distortion THD
< 5 %
Power Factor (cos phi)
1
GENERAL DATA
Max. efficiency
95.2%
Consumption during operation
7 W
Enclosure
NEMA 3R
Size (L x W x H)
18.5 x 16.5 x 8.8 (in)
Weight
26 lb
Ambient temperature range
-5 to 122F
Cooling
controlled forced ventilation
Integrated AC and DC disconnects
standard UL approved DC & AC disconnects
PROTECTIONS
Ground fault protection
Internal GFDI, in accordance with UL 1741
DC reverse polarity protection
Internal diode
Islanding protection
Internal, in accordance with UL 1741, IEEE 1547
Over temperature
Output power derating
Surge protection
Internal DC & AC protection, Tested to 6 kV
COMPLIANCE
Safety
UL 1741
EMI
FCC Part 15; Class A & B
Anti-Islanding protection
UL 1741, IEEE 1547
Ground fault detector and interrupter
Compliant with NEC Art. 690 requirement, UL 1741
MISCELLANEOUS
Maximum AC over current protection
Two-pole, 15 / 20 A circuit breaker
AC wire sizing
Use maximum AWG 6 194F cooper wire
DC wire sizing
Use maximum AWG 8 194F cooper wire
AC disconnect
16 A
DC disconnect
25 A